Cheat Sheet

PFTs and Oxygen Delivery

Spirometry, DLCO, oxygen devices, COPD targets and aerosols

Reviewed by Alex G, BSN, RN, CEN, CCRN, CMC, NREMT-P · Checked against current sources November 2026

Page 1 of the PFTs and Oxygen Delivery PDF, a printed page in columns with sections on Spirometry: obstruction or restriction?, Bronchodilator response and DLCO, Oxygen devices, COPD and oxygen targets, Humidity and aerosols and Oxygen hazardsEnlarge

One-page PDFLetter landscape, ready to print or keep with your notes

View PDFDownload

PFTs and Oxygen Delivery: one-page PDF preview

Page 1 of the PFTs and Oxygen Delivery PDF, a printed page in columns with sections on Spirometry: obstruction or restriction?, Bronchodilator response and DLCO, Oxygen devices, COPD and oxygen targets, Humidity and aerosols and Oxygen hazards

View PDFDownload

Spirometry: obstruction or restriction?

LLN = lower limit of normal (z-score −1.645). Low ratio plus low TLC = mixed pattern.
FindingObstructiveRestrictive
FEV₁/FVCLowNormal or high
FVCNormal or lowLow
TLCNormal or highLow (confirms it)
RVHigh (air trapping)Low; high in neuromuscular weakness

Bronchodilator response and DLCO

VA = alveolar volume; KCO = DLCO ÷ VA. Correct for hemoglobin.
DLCOThink of
Low; low VA and KCOInterstitial lung disease
Low; normal VAEmphysema, pulmonary vascular disease, anemia
Low; low VA, normal or high KCOChest wall or neuromuscular (poor expansion)
HighAlveolar hemorrhage, polycythemia, high blood flow, some asthma

Oxygen devices

Low-flow: below inspiratory demand, so FiO₂ varies. High-flow: meets demand, so FiO₂ is fixed.

Typical adult exam values; sources differ, so follow your institution's protocols. Cannula: about +4% per L/min.
DeviceFlowApprox. FiO₂Type
Nasal cannula1–6 L/min24–44%Low
Simple mask5–10 L/min35–50%Low
Nonrebreather10–15 L/min60–80%Low, reservoir
VenturiMinimum on jet24–60%High
High-flow cannulaUp to 60 L/min21–100%High

COPD and oxygen targets

Humidity and aerosols

SituationHumidity
Low-flow O₂Usually none; AARC: consider above 4 L/min
HFNCAlways heated and humidified
Ventilator, heated33–44 mg H₂O/L, 34–41 °C at Y-piece
Ventilator, HME≥30 mg H₂O/L; not with low tidal volumes
NIVActive humidity; no HME

Oxygen hazards

In depth

The one-page summary above is what the PDF prints. These sections go further.

Lung volumes and how they are measured

Four volumes that do not overlap combine into four capacities. Functional residual capacity (FRC), the resting end-expiratory volume, is where lung recoil balances the outward spring of the chest wall. It is the oxygen store between breaths, and it shrinks when supine and with obesity, abdominal distension and anesthesia, which is why dependent lung collapses. Residual volume (RV) is the gas that cannot be exhaled.

Guyton and Hall textbook values; about 20–25% smaller in women.
Volume or capacityMade ofYoung adult man
Tidal volume (VT)One quiet breath500 mL
Inspiratory reserve volume (IRV)Maximal inhalation above VT3,000 mL
Expiratory reserve volume (ERV)Maximal exhalation below VT1,100 mL
Residual volume (RV)Left after maximal exhalation1,200 mL
Inspiratory capacity (IC)VT + IRV3,500 mL
Functional residual capacity (FRC)ERV + RV2,300 mL
Vital capacity (VC)IRV + VT + ERV4,600 mL
Total lung capacity (TLC)VC + RV5,800 mL

Spirometry cannot measure RV, FRC or TLC. Helium dilution and nitrogen washout count only gas in contact with open airways, so they underestimate volume when gas is trapped, while a helium leak overestimates it. Body plethysmography applies Boyle's law as the patient pants against a closed shutter and counts all the gas in the chest, so it is preferred in obstruction.

TLC below the lower limit of normal (classically under 80% predicted) defines restriction; over 120% is hyperinflation. A high RV or RV/TLC ratio means air trapping, but the ratio (about 21% in the table) rises with age, so ERS/ATS 2022 uses the age-specific upper limit instead of the fixed 35–40% of older teaching.

Spirometry: technique, patterns and bronchodilator response

ATS/ERS 2019: the seated patient inhales fully, blasts out without hesitation and keeps blowing until volume changes by 0.025 L or less over 1 second, or for 15 seconds. The back-extrapolated volume must be under 5% of FVC or 0.100 L, whichever is greater, and a cough in the first second voids the FEV₁. Relative contraindications include MI within 1 week, unstable PE, pneumothorax and thoracic, abdominal or brain surgery within 4 weeks.

ERS/ATS 2022 reads each value against the lower limit of normal (z-score −1.645), and ATS 2023 recommends race-neutral GLI equations. GOLD's fixed 0.70 ratio overcalls obstruction in older adults and misses it in the young. Spirometry cannot confirm restriction: when obstruction comes with a low FVC, TLC is low in only about 10% (Barkous 2024).

PRISm = preserved ratio impaired spirometry, the label used when TLC is unknown.
PatternFEV₁/FVCFVCTLC
ObstructiveLowNormal, or low from trappingNormal or high
RestrictiveNormal or highLowLow
MixedLowLowLow
Non-specificNormalLow, with low FEV₁Normal
PRISmNormalLow FEV₁ and/or FVCNot measured

Bronchodilator testing commonly gives four 100-µg puffs of albuterol by spacer and repeats spirometry about 15 minutes later. ERS/ATS 2022 counts a rise in FEV₁ or FVC of more than 10% of predicted; the 2005 rule, still on many reports, was at least 12% and 200 mL above baseline. Example: predicted FEV₁ 3.00 L, pre 1.80 L, post 2.15 L. The 0.35 L gain is 11.7% of predicted and 19% above baseline, positive by both rules. A negative test does not exclude asthma.

Flow-volume loops and upper-airway obstruction

Normally the expiratory limb peaks early and falls almost linearly, and the inspiratory limb is a smooth U. Obstruction scoops the expiratory limb, with a sharp drop after the peak in severe emphysema; restriction gives a small, tall, narrow loop.

A central-airway lesion flattens a limb into a plateau, and the pressure around the lesion decides which. Outside the chest a floppy segment narrows on forced inspiration, when airway pressure falls below atmospheric. Inside the chest it narrows on forced expiration, when pleural pressure exceeds airway pressure. A rigid lesion limits both.

Expiratory ÷ inspiratory flow at mid-vital capacity. Also suggestive: FEV₁ (mL) ÷ PEF (L/min) over 10, the Empey index (Modrykamien 2009).
LesionLoopExamplesMEF₅₀/MIF₅₀
Variable extrathoracicFlat inspiratory limbVocal cord paralysis or dysfunction, laryngeal tumorOver 1
Variable intrathoracicFlat expiratory limbTracheomalacia, lower tracheal tumorUnder 0.3
FixedBoth limbs flat (box)Post-intubation or tracheostomy stenosisAbout 1

Loops are insensitive: against endoscopy or CT, even a combined criterion found only 69% of obstructions (Modrykamien 2009, 475 loops), and COPD or asthma can hide the plateaus. Suspect a central lesion when dyspnea or stridor ignores bronchodilators, especially after prolonged intubation or tracheostomy, and confirm it with CT or bronchoscopy.

Diffusing capacity (DLCO)

In the single-breath test (ERS/ATS 2017) the patient exhales to RV, takes a full breath of gas with about 0.3% CO and a tracer, holds 10 seconds and exhales. Tracer dilution gives alveolar volume (VA) and CO uptake gives DLCO, about 25–30 mL/min/mm Hg in a healthy man. Repeat tests at least 4 minutes apart should agree within 2 mL/min/mm Hg.

Uptake depends on membrane area and thickness and on capillary blood volume and hemoglobin. Anemia and carboxyhemoglobin from smoking lower the result, so labs adjust for hemoglobin; polycythemia, alveolar hemorrhage, high pulmonary blood flow, lying supine and obesity raise it. KCO (DLCO ÷ VA) separates a small lung from a damaged one: weakness, chest wall disease, effusion or resection give a low DLCO with a normal or high KCO.

ATS/ERS 2005 graded a low DLCO as mild above 60% predicted, moderate 40–60% and severe under 40%; ERS/ATS 2022 uses z-scores. An isolated low DLCO warrants echocardiography and CT.
ConditionSpirometryTLCDLCO
EmphysemaObstructiveNormal or highLow
AsthmaObstructive, often reversibleNormal or highNormal or high
Chronic bronchitisObstructiveNormalNormal
Interstitial lung diseaseRestrictiveLowLow
Neuromuscular or chest wallRestrictiveLowLow or normal; KCO high
Pulmonary vascular diseaseNormalNormalLow (isolated)

Oxygen devices and FiO₂ delivery

Low and high flow compare the device's flow with the patient's demand; they say nothing about FiO₂. A resting adult inhales at about 30 L/min (500 mL in 1 second), and peak flow in distress often exceeds 60 L/min. Below demand, room air makes up the difference and FiO₂ falls as breathing gets faster and deeper. A device that meets demand fixes FiO₂, so a 24% Venturi mask is high flow and a nonrebreather is low flow with a reservoir.

Cannula FiO₂ rises about 4% per L/min up to 6 L/min, even with mouth breathing. A simple mask needs at least 5 L/min to flush CO₂. Published FiO₂ values for the valveless partial rebreather range from about 35% to 85%. Keep a nonrebreather's bag from collapsing on inspiration; leaks lower its FiO₂.

Venturi masks fix FiO₂ by jet and port size. More oxygen raises total flow, not FiO₂; BTS 2017 advises more than the printed minimum when the rate is over 30. Covered ports or kinked or water-filled tubing add back-pressure, so FiO₂ rises and total flow falls.

Air:O₂ = (100 − FiO₂%) ÷ (FiO₂% − 21); total flow = O₂ flow × total parts.
FiO₂Air:O₂Total partsO₂ flow → total flow (L/min)
24%25:1263 → 78
28%10:1114 → 44
35%5:168 → 48
40%3:148 → 32
50%1.7:12.712 → 32
60%1:1215 → 30

Mixed gases: 30 L/min of air plus 10 L/min of O₂ gives (30 × 0.21 + 10) ÷ 40 = 0.41. Cylinder minutes = psi × factor ÷ L/min, with factors of 0.16 (D), 0.28 (E) and 3.14 (H or K); a full E cylinder at 2,200 psi lasts about 60 minutes at 10 L/min.

High-flow nasal cannula and the ROX index

HFNC delivers gas at about 37 °C and full humidity at up to 60 L/min, with FiO₂ 0.21–1.0. Matching inspiratory flow keeps the delivered FiO₂ near the set value, and flushing nasopharyngeal dead space lowers the minute ventilation needed. The flow adds a small pressure: about 2–3 cm H₂O at 30–50 L/min with the mouth closed, and less with it open (Parke 2011). Patients can talk and eat.

FLORALI 2015 (n = 310, nonhypercapnic, P/F ≤300) found intubation in 38% with HFNC, 47% with standard oxygen and 50% with NIV (P = 0.18), but lower 90-day mortality with HFNC. Rochwerg 2020 strongly recommends HFNC over conventional oxygen in hypoxemic failure and suggests it after extubation, where Hernández 2016 cut low-risk reintubation from 12.2% to 4.9%. ERS 2022 prefers NIV for high-risk extubations and a trial of NIV first in hypercapnic COPD.

Start at 40–60 L/min (FLORALI used 50) with FiO₂ titrated to the SpO₂ target and prongs filling no more than half of each naris. Weaning protocols vary; a common one lowers FiO₂ to about 0.40 first, then flow in 5–10 L/min steps to 20–30 L/min.

ROX = (SpO₂ ÷ FiO₂) ÷ respiratory rate (Roca 2019, 191 patients with pneumonia).
Hours on HFNCLower risk of intubationHigh risk of failure
2ROX 4.88 or moreUnder 2.85
6ROX 4.88 or moreUnder 3.47
12ROX 4.88 or moreUnder 3.85

Example: SpO₂ 92% on FiO₂ 0.60 at a rate of 32 gives 153 ÷ 32 = 4.8. A ROX that does not climb over 12 hours is a warning. Late intubation is linked to worse outcomes: after 48 hours of failing HFNC, ICU mortality was 66.7%, against 39.2% with earlier intubation (Kang 2015, retrospective).

Oxygen toxicity, targets and hyperbaric oxygen

Excess oxygen forms reactive oxygen species that injure the lung: tracheobronchitis and a falling vital capacity first, diffuse alveolar damage later. High FiO₂ also causes absorption atelectasis as nitrogen washes out of poorly ventilated alveoli, constricts coronary and cerebral vessels, worsens hypercapnia in patients at risk and causes retinopathy in preterm infants. After bleomycin or in paraquat poisoning, TSANZ 2022 targets an SpO₂ of about 85%.

BTS 2017 and AARC 2022 aim for 94–98% in most acutely ill adults and 88–92% with hypercapnic risk; TSANZ 2022 uses 92–96% and 88–92%. BTS allows 94–98% for an at-risk patient whose PaCO₂ is normal, unless they have needed NIV or intubation for hypercapnic failure before. DETO2X-AMI 2017 (n = 6,629) found no benefit from oxygen in suspected MI without hypoxemia.

IOTA 2018 (25 trials, 16,037 patients): liberal oxygen raised in-hospital mortality (relative risk 1.21).
TrialPatientsTargets comparedResult
Oxygen-ICU 2016434, ICU stay ≥72 hPaO₂ 70–100 vs up to 150ICU death 11.6% vs 20.2%; stopped early
LOCO2 2020205 with ARDSPaO₂ 55–70 vs 90–105Stopped; 90-day death 44.4% vs 30.4%
HOT-ICU 20212,928 hypoxemicPaO₂ 60 vs 90 mm Hg90-day death 42.9% vs 42.4%
PILOT 20222,541 ventilatedSpO₂ 90 vs 94 vs 98%No difference in ventilator-free days
UK-ROX 202516,500 ventilatedSpO₂ 88–92% vs usual90-day death 35.4% vs 34.9%

The trials show harm from liberal oxygen and from a PaO₂ of 55–70 in ARDS, and no difference between a PaO₂ of about 60 and 90 mm Hg. Turn FiO₂ down whenever SpO₂ sits at the top of its range, and check a low-normal SpO₂ with a gas in patients with darker skin (Sjoding 2020).

Hyperbaric oxygen gives 100% O₂ at 2.0–3.0 atmospheres absolute (ATA). At 3 ATA PaO₂ nears 2,000 mm Hg and dissolved oxygen (0.003 × PaO₂) reaches about 6 mL/dL, enough for resting needs, and Boyle's law shrinks bubbles to a third. Carboxyhemoglobin's half-life falls from about 5 hours on air to 74 minutes on 100% O₂ (Weaver 2000) and about 20 minutes in the chamber. UHMS indications include gas embolism, decompression sickness, CO poisoning, gas gangrene, necrotizing infection, crush injury, selected diabetic wounds, radiation injury, compromised flaps and sudden hearing loss.

For CO, three hyperbaric sessions in 24 hours cut 6-week cognitive sequelae from 46.1% to 25.0% (Weaver 2002); Hampson 2012 advises hyperbaric oxygen for loss of consciousness, neurologic deficits, cardiac ischemia, severe acidosis or COHb over 25%. Trials conflict, so ACEP 2017 accepts either hyperbaric or high-flow normobaric oxygen.

Humidification and aerosol delivery

Inspired gas reaches 37 °C and 44 mg H₂O/L at the isothermic saturation boundary, about 5 cm below the carina; an artificial airway moves it deeper, drying mucosa and thickening secretions until they plug the tube. AARC 2012: humidify every invasively ventilated patient, with 33–44 mg/L at 34–41 °C at the Y-piece from a heated humidifier or at least 30 mg/L from an HME, and avoid HMEs with low tidal volumes and in NIV. Classic HME contraindications (AARC 1992): thick, copious or bloody secretions, exhaled volume under 70% of delivered, temperature under 32 °C, minute ventilation over 10 L/min and in-line aerosol. Drain condensate away from the patient, never back into the humidifier.

Particles of 1–5 µm reach the lower airways; larger ones impact in the throat, more so with fast inhalation. AARC 2012 (Ari and Restrepo): a nebulizer or pMDI with valved holding chamber for children 4 or under and adults who cannot coordinate, DPIs from age 4 with enough flow, and no blow-by. In acute asthma a pMDI with chamber matches a nebulizer (Cochrane 2013).

DeviceBreathKey points
pMDISlow and deep, then 10-s holdShake and prime; actuate as the breath starts
pMDI with valved chamberSame, or 5–6 tidal breaths by maskOne puff at a time; a whistle means too fast
DPIFast and forcefulNo spacer; never exhale into it
Soft mist inhalerSlow and deepSlow plume needs little coordination
Jet nebulizerTidal, mouthpiece preferred4–5 mL fill at 6–8 L/min; 0.5–1 mL left
Vibrating mesh nebulizerTidalLittle residual; adds no gas flow

On the ventilator, fire a pMDI into a chamber spacer in the inspiratory limb at the Y-piece as a breath starts. Nebulizer position is debated, and nebulizers put under 20% of the dose into the lungs (Dugernier 2017). A jet nebulizer on a separate flowmeter adds flow, raising tidal volume and FiO₂ and hindering triggering, so prefer the ventilator's nebulizer function or a mesh nebulizer. Remove the HME, and judge response by a smaller peak-to-plateau difference and less auto-PEEP.

Airway clearance and lung expansion

Lung expansion raises transpulmonary pressure, either by lowering pleural pressure (deep breathing, incentive spirometry) or by raising airway pressure (CPAP, PEP, IPPB). AARC 2011 does not recommend incentive spirometry alone for routine postoperative use; pair it with deep breathing, directed coughing, early mobilization and analgesia. Teach a slow inhalation, a 3–5 second hold and about 10 breaths an hour while awake; patients who cannot reach a vital capacity of about 10 mL/kg need positive pressure.

AARC 2013 (patients without cystic fibrosis): no chest physiotherapy for uncomplicated pneumonia, no routine clearance in COPD, early mobilization after surgery, and cough assistance in neuromuscular disease when peak cough flow is under 270 L/min. In cystic fibrosis the order is bronchodilator, mucoactive agent, airway clearance, then inhaled antibiotic or steroid.

TechniqueTypical useAvoid or take care
Postural drainage and percussionAffected segment uppermostICP over 20, instability, hemoptysis, rib fractures
PEP or oscillating PEP10–20 cm H₂O, 10–20 breaths, then huffUntreated pneumothorax, active hemoptysis
Chest wall oscillation vest5–20 Hz for 20–30 minUnstable chest or spine injury
Insufflation–exsufflationOften +40/−40 cm H₂O, 4–5 cycles a setBullae, recent barotrauma
Huff or assisted coughOpen-glottis exhalation; abdominal thrustThrust after abdominal surgery

Diaphragm weakness: supine vital capacity, MIP and SNIP

Vital capacity (VC) measured seated and then supine is a simple bedside test of the diaphragm: a weak diaphragm loses more volume when the patient lies flat. The upright value and the size of the supine fall separate one weak hemidiaphragm from two. Supine fall = (upright VC − supine VC) ÷ upright VC; for example, 3.00 L upright and 2.00 L supine is a fall of 33%.

Dubé and Dres 2016. In neuromuscular disease a supine fall of more than 25% was 90% specific and 79% sensitive for diaphragm weakness (Fromageot 2001).
PatternUpright VCFurther fall when supine
One hemidiaphragm weakAbout 75% of predicted10% to 20%
Both hemidiaphragms weakAbout 50% of predicted30% to 50%

One weak hemidiaphragm can cause no symptoms, and FRC and TLC are usually preserved. Weakness of both hemidiaphragms very often causes severe dyspnea when supine and on exertion, with sleep-disordered breathing; TLC can fall and RV can rise.

Maximal inspiratory pressure (MIP) is measured at the mouth against a closed mouthpiece, from residual volume or from FRC; values from residual volume are about 30% higher. The maneuver is not intuitive and needs cooperation, a maximal effort held for 1 to 2 seconds and a tight lip seal, so a low value may reflect technique or a leak and not weakness. A MIP more negative than −80 cm H₂O generally excludes clinically significant inspiratory muscle weakness.

Sniff nasal inspiratory pressure (SNIP) tests the same muscles without a mouthpiece. A pressure probe plugs one nostril, the other nostril stays open, and the patient makes short, sharp, maximal sniffs from FRC with the mouth closed; the highest of at least 10 sniffs is used. The sniff is a natural maneuver, the result reflects esophageal pressure, and it suits patients whose facial weakness prevents a tight seal around a mouthpiece. Lower limits of normal are about 70 cm H₂O in men and 60 cm H₂O in women.

Phrenic nerve block after an interscalene block

The phrenic nerve arises from C3 to C5 and descends in front of the scalene muscles, close to where an interscalene brachial plexus block for shoulder surgery is placed, so the local anesthetic often reaches it and paralyzes the hemidiaphragm on the side of the block. In a 2026 systematic review of 33 randomized trials (1,481 patients), hemidiaphragm paralysis occurred in an average of 53% of patients, with mean falls of about 27% in FEV₁ and 25% in FVC.

The paralysis is transient and healthy patients usually tolerate it. Older patients and those with reduced cardiopulmonary reserve are at higher risk of severe hypoxemia and respiratory failure. The chest radiograph shows a raised hemidiaphragm on the blocked side; that sign is sensitive (about 90%) but is often a false positive, because atelectasis, a mass or a process under the diaphragm can also raise it, so bedside ultrasound of diaphragm thickening and excursion is used to confirm the weakness.

Chest radiograph: the silhouette sign and lobar collapse

A border shows on a radiograph only where structures of different density meet. When a lesion in the chest touches the heart, the aorta or the diaphragm, that border disappears; a lesion that does not touch the structure leaves the border sharp. This is the silhouette sign (Felson), and the border that is lost names the lobe.

Kumaresh 2015. Lower lobe disease leaves the heart border visible, which separates right lower lobe from right middle lobe disease (Khan 2009).
Border lostDisease is in
Right heart borderRight middle lobe
Left heart borderLingula
Hemidiaphragm or descending aortaLower lobe
Right paratracheal stripeRight upper lobe, anterior segment
Aortic knuckleLeft upper lobe, apicoposterior segment

Signs of lost volume point to atelectasis and not to other causes of consolidation: a raised hemidiaphragm, a displaced fissure, crowded vessels and shift of the mediastinum. Collapsed lobes also follow fixed anatomical paths.

Khan 2009.
Collapsed lobeFrontal film
Right upperTriangular opacity; minor fissure pulled up and medially
Right middleSubtle; right heart border lost; clearer on a lateral film
Right lowerTriangular opacity toward the lower spine; right hemidiaphragm lost, heart border kept
Left upperHazy, raised left hilum; upper left heart border lost; air crescent beside the aortic arch (Luftsichel)
Left lowerTriangular opacity behind the heart; left hemidiaphragm lost; easily missed on an underpenetrated film

In ICU patients atelectasis is seen most often in the left lower lobe, thought to be because the heart compresses the lower lobe bronchus in the supine patient and blind suctioning reaches that lobe less easily. An acute mucus plug can cause sudden hypoxemia with a nearly normal film.

Bronchiectasis, hepatopulmonary syndrome, hypersensitivity pneumonitis and valley fever: the confirming test

ConditionClueConfirming test
BronchiectasisChronic cough, thick purulent sputumHigh-resolution CT of the chest
Hepatopulmonary syndromeLiver disease, hypoxemia worse uprightContrast echocardiography and an upright ABG
Hypersensitivity pneumonitisIllness hours after each exposureExposure history, HRCT, BAL lymphocytosis
CoccidioidomycosisPneumonia after dust in the SouthwestSerology, starting with enzyme immunoassay

Bronchiectasis: suspect it with persistent mucopurulent or purulent sputum and repeated chest infections; crackles, rhonchi and wheezes are typical and clubbing is uncommon. A chest radiograph comes first, but high-resolution (thin-section) CT is the imaging test of choice and confirms the diagnosis: a bronchus wider than the artery beside it (signet ring sign), bronchi that do not taper, and airways visible within 1 cm of the pleura, often with thick walls and mucus plugs. Pulmonary function tests give a baseline and follow progression but may be normal. After CT, look for a cause and for organisms: sputum for routine and mycobacterial culture, serum immunoglobulins, total IgE and Aspergillus sensitization, and a sweat chloride test when cystic fibrosis is possible (BTS 2019; Merck Manual).

Hepatopulmonary syndrome is three findings together: liver disease or portal hypertension; intrapulmonary vascular dilatations or shunting; and an alveolar-arterial oxygen gradient of 15 mm Hg or more (over 20 mm Hg at age 65 or older) on a room-air blood gas drawn sitting upright. It affects 10% to 30% of patients evaluated for liver transplant and is often silent. Clubbing, cyanosis and telangiectasias may be present. Platypnea (dyspnea that worsens on moving from supine to upright) and orthodeoxia (a PaO₂ fall of more than 5% or more than 4 mm Hg from supine to upright) are the classic signs, but only about a fifth of patients have them.

Contrast echocardiography with agitated saline shows the dilatations. The bubbles normally stay in the right heart; bubbles that reach the left heart 3 or more cardiac cycles after the right heart mean an intrapulmonary shunt, and bubbles within 3 cycles mean an intracardiac shunt. Severity follows the upright PaO₂: mild 80 mm Hg or more, moderate 60 to 79, severe 50 to 59, very severe under 50. A low DLCO is usual but is common in cirrhosis without the syndrome. Long-term oxygen is supportive, and liver transplant is the only effective treatment (Raevens 2022).

Hypersensitivity pneumonitis develops in susceptible people after repeated inhalation of an antigen, usually a protein from microorganisms, fungi or animals: bird droppings or feathers (bird fancier's lung), moldy hay or grain (farmer's lung), contaminated hot tub mist (hot tub lung). Acute disease brings fever, chills, cough, chest tightness and dyspnea 4 to 8 hours after exposure, so repeated febrile chest illnesses that follow an exposure are the clue, and a thorough exposure history (home, work, birds, water sources) is the first step. HRCT of nonfibrotic disease shows ill-defined centrilobular nodules, ground-glass opacity and mosaic attenuation, with air trapping on expiratory images. BAL lymphocytosis supports it (over 40% in the Merck Manual; the ATS/JRS/ALAT 2020 guideline treats 30% as a reasonable threshold), and serum IgG to the antigen can help. No single finding is enough by itself; an identified exposure with a typical HRCT pattern and BAL lymphocytosis gives a confident diagnosis. Avoiding the antigen is the most important part of long-term management.

Coccidioidomycosis (valley fever) follows inhalation of spores of a soil fungus of the southwestern United States, highly endemic in southern Arizona and California's southern San Joaquin Valley, and of parts of Mexico and Central and South America. Work that disturbs soil (digging, construction, agriculture) raises the risk. Symptoms start 1 to 3 weeks after exposure and resemble community-acquired pneumonia; it causes an estimated 15% to 30% of community-acquired pneumonia in highly endemic areas of Arizona. Clues are erythema nodosum, arthritis, eosinophilia and a pneumonia that does not improve on antibiotics.

CDC advises testing patients with pneumonia who live in or have traveled to an endemic area, above all when empiric antibiotics have not helped. Order an enzyme immunoassay (EIA) for coccidioidal IgM and IgG, with immunodiffusion or complement fixation to confirm; if the first test is negative and suspicion remains, repeat serology in 2 to 6 weeks. Tell the laboratory when the infection is suspected, because cultures are a serious biohazard to staff and are handled at biosafety level 3.

Breathing patterns in coma and the level of injury

In a comatose patient the spontaneous rate and pattern of breathing help localize the injury (Merck Manual). The order in which these patterns appear during herniation is on Neuro: ICP and Stroke, and Cheyne–Stokes breathing in heart failure is on Sleep Medicine and Chronic Lung Care.

Merck Manual; ataxic row from Tirapé-Castro 2026. The Merck Manual lists Biot respiration beside Cheyne–Stokes as periodic breathing of the hemispheres or diencephalon; its classic association, as ataxic breathing, is with the medulla or lower pons.
PatternWhat is seenSuggests
Cheyne–StokesPeriodic cycling: breaths build and fade in a regular crescendo and decrescendo, with apneas betweenBoth cerebral hemispheres or the diencephalon
Central neurogenic hyperventilationSustained rate over 25 breaths/minMidbrain or upper pons
ApneusticInspiratory gasp, then a pause of about 3 seconds at full inspirationPons or medulla
Ataxic (Biot)Irregular clusters of breaths separated by apneic pauses of varying lengthMedulla or lower pons

NBRC emphasis and exam pearls

The 2027 NBRC RT outline lists spirometry, lung volumes, DLCO, peak flow, MIP, MEP, MVV, SpO₂/FiO₂ and oxygen titration with exercise. Device troubleshooting fills 19 of 25 Devices items, from flowmeters and cylinders to heated high-flow systems, humidifiers, nebulizers and inhalers. Hyperbaric oxygen is not a named task.

Practice free in your browser1,900+ exam-style questions with rationales. Free today, no account, no ads. Pro is coming in January 2027. Also free on Google Play.

Related cheat sheets

Calculators for this topic

Sources

  1. National Board for Respiratory Care. The Respiratory Therapy Examination Detailed Content Outline, effective January 2027. Link
  2. Stanojevic S, Kaminsky DA, Miller MR, et al. ERS/ATS technical standard on interpretive strategies for routine lung function tests. Eur Respir J. 2022;60(1):2101499. Link
  3. Barkous B, Briki C, Boubakri S, et al. Routine pulmonary lung function tests: interpretative strategies and challenges. Chron Respir Dis. 2024;21:14799731241307252. Link
  4. Halpin DMG, Stanojevic S, McCormack MC, et al. Joint statement from GOLD/GLI regarding the use of spirometry to define airflow obstruction and diagnose COPD. Eur Respir J. 2026;67(4):2502574. Link
  5. Global Initiative for Chronic Obstructive Lung Disease. Global Strategy for Prevention, Diagnosis and Management of COPD: 2026 Report (v1.3, 8 Dec 2025). Link
  6. Li Y, Lin J, Wang Z, et al. Bronchodilator responsiveness defined by the 2005 and 2021 ERS/ATS criteria in patients with asthma as well as COPD. Int J Chron Obstruct Pulmon Dis. 2022;17:2623-2633. Link
  7. Graham BL, Steenbruggen I, Miller MR, et al. Standardization of Spirometry 2019 Update. An Official ATS and ERS Technical Statement. Am J Respir Crit Care Med. 2019;200(8):e70-e88. Link
  8. Nelson RE, Richards JB. Breathing, Obstruction, Restriction, and Gas Exchange: a pulmonary function testing interpretation framework for novice learners. ATS Sch. 2023;4(2):230-240. Link
  9. O'Driscoll BR, Howard LS, Earis J, Mak V; BTS Emergency Oxygen Guideline Group. BTS guideline for oxygen use in adults in healthcare and emergency settings. Thorax. 2017;72(Suppl 1):i1-i90. Link
  10. British Thoracic Society. Emergency Oxygen: Target Oxygen Saturation (guideline in development). Link
  11. Piraino T, Madden M, Roberts KJ, et al. AARC Clinical Practice Guideline: Management of Adult Patients With Oxygen in the Acute Care Setting. Respir Care. 2022;67(1):115-128. Link
  12. Burkhart JE Jr, Stoller JK. Oxygen and aerosolized drug delivery: matching the device to the patient. Cleve Clin J Med. 1998;65(4):200-208. Link
  13. Ernstmeyer K, Christman E, eds. Nursing Skills (Open RN). Chapter 11.3, Oxygenation Equipment. Chippewa Valley Technical College; 2021, via LibreTexts. Link
  14. Hardavella G, Karampinis I, Frille A, Sreter K, Rousalova I. Oxygen devices and delivery systems. Breathe (Sheff). 2019;15(3):e108-e116. Link
  15. Barnett A, Beasley R, Buchan C, et al. Thoracic Society of Australia and New Zealand position statement on acute oxygen use in adults: 'Swimming between the flags'. Respirology. 2022;27(4):262-276. Link
  16. Batool S, Garg R. Appropriate use of oxygen delivery devices. Open Anesthesiol J. 2017;11:35-38. Link
  17. Lipnick M, Sendagire C, Kallet R, Branson R, Silvers R. Overview of oxygen delivery devices. OpenCriticalCare.org, updated February 28, 2023. Link
  18. Rochwerg B, Einav S, Chaudhuri D, et al. The role for high flow nasal cannula as a respiratory support strategy in adults: a clinical practice guideline. Intensive Care Med. 2020;46(12):2226-2237. Link
  19. Fisher & Paykel Healthcare. Airvo 3 product page. Link
  20. Restrepo RD, Walsh BK. Humidification during invasive and noninvasive mechanical ventilation: 2012. Respir Care. 2012;57(5):782-788. Link
  21. Ari A, Restrepo RD. Aerosol delivery device selection for spontaneously breathing patients: 2012. Respir Care. 2012;57(4):613-626. Link
  22. Centers for Medicare & Medicaid Services. National Coverage Determination 240.2: Home Use of Oxygen (effective September 27, 2021). Link
  23. Patel BK. Overview of Mechanical Ventilation. Merck Manual Professional Version, reviewed June 2026. Link
  24. Cummings JJ, Polin RA; AAP Committee on Fetus and Newborn. Oxygen targeting in extremely low birth weight infants. Pediatrics. 2016;138(2):e20161576. Link
  25. Dubé BP, Dres M. Diaphragm dysfunction: diagnostic approaches and management strategies. J Clin Med. 2016;5(12):113. Link
  26. Fromageot C, Lofaso F, Annane D, et al. Supine fall in lung volumes in the assessment of diaphragmatic weakness in neuromuscular disorders. Arch Phys Med Rehabil. 2001;82(1):123-128 (abstract). Link
  27. Caruso P, Albuquerque AL, Santana PV, et al. Diagnostic methods to assess inspiratory and expiratory muscle strength. J Bras Pneumol. 2015;41(2):110-123. Link
  28. Kaminska M, Noel F, Petrof BJ. Optimal method for assessment of respiratory muscle strength in neuromuscular disorders using sniff nasal inspiratory pressure (SNIP). PLoS One. 2017;12(5):e0177723. Link
  29. Karve Z, Williams C, Calpey J, Movassaghi A, Lubert J, Sabesan VJ. Pulmonary impairment after interscalene block for orthopedic shoulder surgery: a systematic review. JSES Rev Rep Tech. 2026;6(4):100818. Link
  30. Kumaresh A, Kumar M, Dev B, Gorantla R, Sai PV, Thanasekaraan V. Back to basics: 'must know' classical signs in thoracic radiology. J Clin Imaging Sci. 2015;5:43. Link
  31. Khan AN, Al-Jahdali H, Al-Ghanem S, Gouda A. Reading chest radiographs in the critically ill (Part II): radiography of lung pathologies common in the ICU patient. Ann Thorac Med. 2009;4(3):149-157. Link
  32. Hill AT, Sullivan AL, Chalmers JD, et al. British Thoracic Society guideline for bronchiectasis in adults. BMJ Open Respir Res. 2018;5(1):e000348. Link
  33. Steinbach T. Bronchiectasis. Merck Manual Professional Version, reviewed April 2025. Link
  34. Raevens S, Boret M, Fallon MB. Hepatopulmonary syndrome. JHEP Rep. 2022;4(9):100527. Link
  35. Raghu G, Remy-Jardin M, Ryerson CJ, et al. Diagnosis of hypersensitivity pneumonitis in adults. An official ATS/JRS/ALAT clinical practice guideline. Am J Respir Crit Care Med. 2020;202(3):e36-e69. Link
  36. Lee J. Hypersensitivity Pneumonitis. Merck Manual Professional Version, reviewed June 2025. Link
  37. Centers for Disease Control and Prevention. Clinical Overview of Valley Fever (January 31, 2025) and Clinical Testing Algorithm for Valley Fever (May 10, 2024). Link
  38. Vergidis P. Coccidioidomycosis. Merck Manual Professional Version, reviewed November 2025. Link
  39. Williams SL, Chiller T. Update on the epidemiology, diagnosis, and treatment of coccidioidomycosis. J Fungi (Basel). 2022;8(7):666. Link
  40. Schiff N. Overview of Coma and Impaired Consciousness. Merck Manual Professional Version, reviewed July 2026. Link
  41. Tirapé-Castro HA, Cajamarca-Sacta LC, Martínez-Arias F, Solís-Manzano AM, Cevallos Morejón PG, Ruiz-Flores A. Biot's respiratory pattern under mechanical ventilation: two case reports and literature review. Respir Med Case Rep. 2026;61:102403. Link